Viking’s own 2010 factory service manual for the VUWC244DRSS documents its TruProtect alarm system in detail, with E1 through E4 codes each tied to a specific part: the compressor, the condenser fan, or one of the two compartment thermistor sensors. The manual also notes that any of these codes can follow a power surge, a low-voltage condition, or an outage, and should be retested after a power-on reset before assuming a hardware problem.
Key Features
- 24" dual-zone undercounter wine cellar
- TruProtect alarm system
- Independently controlled upper and lower compartments
- Digital temperature control
Most Common Issues on This Model
E1 Compressor Error (high amps), per Viking's own 2010 service documentation
E2 Condenser Fan Error (low amps)
E3/E4 Compartment Thermistor Sensor Error, upper or lower zone