Viking Ice Machine Diagnostic LED, Two Flashes

Two flashes every five seconds means the bin sensor is reading open or shorted. Viking's VUIM/DUIM150 service manual (2009) spells out the consequence on page 29: when the bin thermistor fails, or reports a temperature outside the 25 to 140…

What 2 Flashes Means

Two flashes every five seconds means the bin sensor is reading open or shorted. Viking's VUIM/DUIM150 service manual (2009) spells out the consequence on page 29: when the bin thermistor fails, or reports a temperature outside the 25 to 140 degree Fahrenheit window, every load is switched off and the machine will not run at all.

Common Causes of 2 Flashes

  • Bin thermistor open or shorted
  • Thermistor not fully inserted into its plated sensing tube, so it never reads the bin properly
  • Connector at the electronic control unplugged or corroded

🔧 One Safe Check You Can Try

Nothing can be tested from the bin, but the behavior is worth recognizing: a machine that has gone completely silent rather than partly working matches this pattern, because the control shuts everything down rather than carrying on without a bin reading.

⚠ Why You Shouldn't Go Further Than That

  • Viking is explicit that the thermistor must be fully inserted into its plated sensing tube for proper detection, and a sensor refitted short of home reports the wrong thing while looking perfectly installed.
  • Reaching the bin thermistor means removing the escutcheon panel, the cutter grid, the ice deflector and the reservoir in sequence, with the water line and drain disconnected first.
  • The thermistor is checked against a published resistance and temperature table to within four per cent, so a reading without that table proves nothing.

Opening a panel to inspect or repair something yourself doesn't automatically cancel your manufacturer's warranty — but it can risk accidental damage, and some manufacturers do have specific service conditions. Check your product's warranty terms, or ask us, before deciding.

Other Ice Machine Error Codes

Still Seeing 2 Flashes?

Book a trained technician and get it diagnosed correctly the first time — no guesswork, no repeat visits.

Book Repair for 2 Flashes

Same-day & next-day appointments · No hidden fees · Technicians trained on these appliances

or call (844) 821-4832 now

FAQ

2 Flashes FAQ

On this design, yes. Viking's control shuts off all loads when the bin thermistor fails, so total silence is the documented response rather than a sign of something worse.

It is what tells the machine when to start and stop making ice. Without it the control has no way to know whether the bin is empty or overflowing, so it stops.

Need a repair? We're ready to help. Call Now
Call Us Schedule